Promag CON-485 Series Technical Information Seite 20

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 40
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 19
Proline Promag 50W, 53W
20 Endress+Hauser
Degree of protection Standard: IP 67 (NEMA 4X) for transmitter and sensor
Optional: IP 68 (NEMA 6P) for sensor in remote version
Shock and vibration resistance Acceleration up to 2 g by analogy with IEC 60068-2-6.
Electromagnetic compatibility
(EMC)
To EN 61326/A1 and NAMUR recommendation NE 21.
Process conditions
Medium temperature range The permissible medium temperature depends on the measuring-tube lining:
0...+80 °C for hard rubber (DN 65...2000)
20...+50 °C for polyurethane (DN 25...1000)
Conductivity Minimum conductivity:
5 µS/cm for liquids generally
20 µS/cm for demineralised water
Note that in the case of the remote version, the minimum conductivity is also influenced by the length of the
connecting cable see “Length of connecting cable”
Medium pressure range
(nominal pressure)
EN 1092-1 (DIN 2501):
PN 6 (DN 1200…2000)
PN 10 (DN 200…2000)
PN 16 (DN 65…2000)
PN 25 (DN 200...1000)
PN 40 (DN 25…150)
ANSI B16.5:
Class 150 (1…24")
Class 300 (1…6")
AWWA:
Class D (28…78")
JIS B2238:
10K (DN 50…300)
20K (DN 25…300)
AS 2129:
Table E (DN 80, 100, 150...400, 500, 600)
AS 4087:
Cl. 14 (DN 80, 100, 150...400, 500, 600)
Pressure tightness
(liner)
Nominal diameter Measuring tube
lining
Resistance to partial vacuum of measuring tube lining
Limit values for abs. pressure [mbar] at various
fluid temperatures
[mm] [inch] 25 °C 50 °C 80 °C 100 °C 130 °C 150 °C 180 °C
25…1000 1…40" Polyurethane 0 0 −−−−−
65…2000 3…78" Hard rubber 0 0 0 −−−−
Seitenansicht 19