Proline Promag 50W, 53W
Endress+Hauser 11
Metal, ungrounded piping
In order to prevent outside influences on measurement, it is advisable to use ground cables to connect each
sensor flange to its corresponding pipe flange and ground the flanges. Connect the transmitter or sensor con-
nection housing, as applicable, to ground potential means of the ground terminal provided for the purpose.
Caution!
Also, observe company-internal grounding guidelines.
Note!
The ground cable for flange-to-flange connections can be ordered separately as an accessory from
Endress+Hauser.
•DN 300: The ground cable is in direct connection with the conductive flange coating and is secured by
the flange screws.
•DN 350: The ground cable connects directly to the metal transport bracket.
A0004376
6 mm² Cu
DN 300£
DN 350³
Seitenansicht 10