3 Installation Memo-Graph S
12 Endress+Hauser
3.3 Installation instructions
3.3.1 Mounting kit
To install the control panel, all you need is a screwdriver.
3.3.2 Panel mounting
Figure 2: Panel mounting for version with die-cast or stainless steel front
Make a panel cutout, 138+1 x 138+1 mm in size (acc. DIN 43700). Please observe the asymmet-
rical alignment of the front bezel to the casing.
The installation depth of the device is approx. 211 mm without, or 232 mm with, rear panel or ter-
minal cover.
1. Attach the control panel seal to the device and push it from the front through the panel cutout.
To avoid heat accumulation, we recommend keeping a distance of > 15 mm from the walls
and other devices.
2. Hold the device level and the hang jack screws in the openings (top/bottom or left/right for
IP54 ingress protection, all four for IP65 ingress protection).
3. Evenly tighten the screws on the jack screws using a screwdriver so that a secure, gap free seal
is guaranteed with the panel (recomended tension on the screws for an IP65 protection is 0.8
to 1.3 Nm).
!
Note!
Another support is only required for very thin control panel versions.
3.4 Post-installation check
After installing the control panel, please check the following points:
• Is the control panel seal mounted?
• Is the device fixed firmly in the control panel?